Process technology · Art. no. HTD‑24000

Lamella hammer-in packer
for mortar injection.

For injecting cement paste, cement suspension, ERGELIT-KBi injection mortar and aqueous solutions – faster to set than screw-in packers and with 0 bar opening pressure.

Mortar injection with ERGELIT-KBi through lamella hammer-in packers in a manhole
Plastic lamella hammer-in packer with sealing lamellae and non-return valve for mortar injection

Precise injection

Tight in the drill hole,
clear in the bore.

The hammer-in packers made of high-quality plastic seal the drill hole reliably by means of lamellae. The opening pressure is 0 bar and the cross-section is not restricted – for optimum injection results with ERGELIT-KBi and cement suspensions.

14 mm drill size, 9.5 cm length, unobstructed passage and a screw-on non-return valve: the packers can be set quickly, can remain in the structure and are corrosion-resistant.

Your benefits

The benefits at a glance.

Fast, corrosion-resistant and practical – for clean and targeted injection work.

0 bar opening pressure

Effortless, precise injection with no restriction of the cross-section.

Faster to set

Considerably faster than screw-in packers – saves time and labour.

With non-return valve

For more targeted injection and a cleaner process.

Stays in the structure

Corrosion-resistant material – or simply remove it again.

Masonry sewer with eroded joints before pressure pointing

For manholes and sewers

Fill voids,
secure masonry.

Whether cement paste, cement suspension or ERGELIT-KBi – the lamella hammer-in packer carries the injection material into the structure precisely and with no restriction of the cross-section.

Technical data

Technology & equipment.

Lamella hammer-in packer made of high-quality plastic – Art. no. HTD‑24000.

Drill size: 14 mm
Length: 9.5 cm
Passage: unobstructed, no restriction of the cross-section
Material: high-quality, corrosion-resistant plastic
Sealing: by lamellae in the drill hole
Opening pressure: 0 bar
Valve: incl. screw-on non-return valve
After injection: can remain in the structure

Application

Six steps
to your injection.

How to use the lamella hammer-in packer correctly for mortar injection.

1. Pre-drill a 14 mm hole
2. Clean the drill hole
3. Hammer in the packer using the setting tool
4. Fit the closure piece
5. Inject using an injection pump
6. Knock off protruding packers